Author |
|
Message | |
|
wellington womble
Joined: 08 Nov 2004 Posts: 15051 Location: East Midlands
|
|
|
|
|
dpack
Joined: 02 Jul 2005 Posts: 46244 Location: yes
|
|
|
|
|
wellington womble
Joined: 08 Nov 2004 Posts: 15051 Location: East Midlands
|
|
|
|
|
dpack
Joined: 02 Jul 2005 Posts: 46244 Location: yes
|
|
|
|
|
onemanband
Joined: 26 Dec 2010 Posts: 1473 Location: NCA90
|
|
|
|
|
dpack
Joined: 02 Jul 2005 Posts: 46244 Location: yes
|
|
|
|
|
wellington womble
Joined: 08 Nov 2004 Posts: 15051 Location: East Midlands
|
|
|
|
|
dpack
Joined: 02 Jul 2005 Posts: 46244 Location: yes
|
Posted: Tue Sep 20, 16 10:29 pm Post subject: |
|
it will help him and you if you make a list of what you need in terms of plugs etc in each room before he comes to quote.
working out exactly where to put them can make quite a difference to the price so be prepared to be flexible but make sure you have enough and a few spare.
i rather like "hoovering plugs" in the open even if there is a spare hole with the general ones that feed the usual items .
if you want to get fancy you can have a lamp circuit as well as a ring main and feed/ control any low level lighting with that, high level lighting is on a normal lighting circuit but again consider dimmers as some leds will work with those.
a full rewire is the proper time to think about lighting , most houses are appallingly lit but they can be appealingly lit with a bit of planning .
if you need power outside/sheds etc decide what you need and get it included, retro fitting afterwards will either cost more or cock up the new system .
a couple of minor but important things ,get the smoke alarms mains powered which is far better than replacing batteries and try to get the spark to fit all switches in convenient for use, rather than convenient to install (or historic), places . too often light switches etc are in a daft place.
depending on your structure it can range from a bit messy and inconvenient to noisy, messy and full redecoration after the plaster dries , discuss options regarding positioning etc and be prepared to be flexible if perfect when done is going to be nightmare and expensive to do try to find the ok when done option.
ps think of a number of kitchen sockets you definitely need and double it, you wont use them all at the same time but the flexibility of having lots is really nice .
neons are good in the kitchen and remind you that something is still on
pps MK materials are not the cheapest but they are good and last far longer than cheaper stuff which long term works out expensive when replacing things in a few years. im very impressed with their antibacterial kitchen plugs which wipe well and dont get scratched in a few months like some do.
have fun planning and end up with a really good practical set of electrics.
ppps , need to know can be very minimal, he will know he messed up (as it is now being done properly ) but not rubbing it in can be more fun than pointing to every error as he will know that you know and have no way to make excuses. |
|
|
|
|
NorthernMonkeyGirl
Joined: 10 Apr 2011 Posts: 4630 Location: Peeping over your shoulder
|
|
|
|
|
john of wessex
Joined: 18 Jun 2007 Posts: 2130
|
|
|
|
|
wellington womble
Joined: 08 Nov 2004 Posts: 15051 Location: East Midlands
|
Posted: Wed Sep 21, 16 9:29 pm Post subject: |
|
That's an idea. I had thought about where I might want plug sockets, but not for cars. I'd love an electric car, especially with the solar power. There is already an outside socket, but I would like a socket in the garage (there is armoured cable already, and the solar people were supposed to put a socket in, but they didn't) I hadn't thought of mains snoke alarms, that would be nice.
There are currently no sockets in the hall, stairs or landing at all, so anything would be an improvement. The kitchen sockets are mostly ok and the light switches are mostly logical, with one exception. I'd quite like kill switches to turn all the power off to a room.
Stepfather is totally, genuinely baffled about why the whole thing is necessary. He just doesn't get why they can't simply fix the fault. Mum is a bit more with it, but still doesn't see why it might be necessary to do any disruptive work. She has just asked me why they can't thread string on to the existing wires and pull new ones through, and then it won't matter about inconvenient ceilings and so on. She doesn't really see why it would need new wiring anyway, either.
I don't know why, but I really want it done properly and if that's what the sparky says needs doing, that's what's happening. Before I decorate anything!
We are even going to get the rising damp done at the same time. My goodness, I know how to live! |
|
|
|
|
dpack
Joined: 02 Jul 2005 Posts: 46244 Location: yes
|
|
|
|
|
wellington womble
Joined: 08 Nov 2004 Posts: 15051 Location: East Midlands
|
|
|
|
|
dpack
Joined: 02 Jul 2005 Posts: 46244 Location: yes
|
|
|
|
|
Nick
Joined: 02 Nov 2004 Posts: 34535 Location: Hereford
|
|
|
|
|
|
Archive