|
|
Author |
|
Message | |
|
Nick
Joined: 02 Nov 2004 Posts: 34535 Location: Hereford
|
|
|
|
|
sean Downsizer Moderator
Joined: 28 Oct 2004 Posts: 42219 Location: North Devon
|
|
|
|
|
Shan
Joined: 13 Jan 2009 Posts: 9075 Location: South Wales
|
|
|
|
|
dpack
Joined: 02 Jul 2005 Posts: 46207 Location: yes
|
|
|
|
|
dpack
Joined: 02 Jul 2005 Posts: 46207 Location: yes
|
|
|
|
|
Nick
Joined: 02 Nov 2004 Posts: 34535 Location: Hereford
|
|
|
|
|
GrahamH
Joined: 23 May 2015 Posts: 523
|
|
|
|
|
dpack
Joined: 02 Jul 2005 Posts: 46207 Location: yes
|
|
|
|
|
Hairyloon
Joined: 20 Nov 2008 Posts: 15425 Location: Today I are mostly being in Yorkshire.
|
|
|
|
|
dpack
Joined: 02 Jul 2005 Posts: 46207 Location: yes
|
Posted: Thu May 09, 19 10:40 pm Post subject: |
|
Hairyloon wrote: |
dpack wrote: |
start by sourcing a decent spark and get it all checked, although a proper job is costly and disruptive there are far worse potential alternatives. |
Or just disconnect it and start again from scratch.
Is probably what a sparky would do. |
that is what i would expect a good spark would suggest for the old/moody stuff but there may be some modern well installed circuits that would pass inspection and are safe to keep.
another thing to consider is if for any reason you wished to rent it out that usually requires an electrical test cert if only for the insurance, if you are staying put for ever it will need replacing sometime and now and once might make sense.
i might be a little adventurous in some ways but some of things i have found in domestic electrical installations are far too interesting to live with.
if it looks iffy on the surface the hidden stuff is likely to be far worse
basically i recon if it does not have a current test cert it probably needs a rewire applies to most properties.
start with the supply and install new properly makes sense.
having worked to that whenever possible it has proven very correct once the old stuff starts getting seen.
even if it was done well time takes it's payment from switches and plugs and cables, stuff like breakers or controllers are even more short lived.
is anything over 25 yrs old?
are the consumer units over 15 yrs old?
plugs n switches it depends on quality and usage but 20 to 25 is getting on a bit
that said i removed what was a functional, 2 core naked copper in wooden trunking lighting circuit from 1897 almost exactly a hundreds years later
it worked but i rather like an earth and preferably some sort of circuit breaker included with the power
a couple of weeks ago i went to london to have a look at some electrics, short version, i went , i saw , i said replace it , i wont turn it back on or even bother putting meters on it as it has multiple zoning, circuit "design", appalling condition and broken bits issues.
much like quite a few of my chums our house is one piece at a time, at least the new circuits are sound and replaced the most urgent problems.
that is fine if you are not doing it for other folk and you get it right.
i would never consider recommending anything apart from start again on an elderly, one piece at a time installation ( new and certified circuits are ok to keep ) |
|
|
|
|
Mistress Rose
Joined: 21 Jul 2011 Posts: 15966
|
|
|
|
|
dpack
Joined: 02 Jul 2005 Posts: 46207 Location: yes
|
|
|
|
|
Mistress Rose
Joined: 21 Jul 2011 Posts: 15966
|
|
|
|
|
gregotyn
Joined: 24 Jun 2010 Posts: 2201 Location: Llanfyllin area
|
|
|
|
|
|